Customization: | Available |
---|---|
Application: | Construction |
Certification: | CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Code | Name | Model | Technical Parameter | Unit | Qty | Remark | |
One | Limestone Crushing Line | ||||||
1 | Jaw Crusher | PE400X600 | 60T/h ,POWER=30kw | Set | 1 | 1.8m*1.8m*1.9m | |
2 | Screening Equipment | 50mm,double screen,upper screen hole 90mm,Down side screen hole 50mm | Set | 1 | 3m*4m*3m | ||
3 | Belt Conveyor | 5.5KW,TD75vtype B650 | Set | 4 | |||
4 | Feeder | 100T/h 650X2300 | Set | 1 | 1m*2.5m*1m | ||
5 | Hopper/Platform/Support/Chute | Making and Welding in site | Ton | 20 | Provide drawing to site | ||
Two | Vertical Kiln Calcining System | ||||||
1 | Refractory Materials | High Aluminium Brick LZ-65 | Ton | 400 | |||
High Aluminium Brick LZ-55 | |||||||
Light Heat Insulation Plate | |||||||
Aluminium silicate refractory fiber | |||||||
2 | Steel structure | Furnace shell,bridge,platform,raw meal hopper | Ton | 250 | provide drawing to site | ||
3 | Hoisting Equipment | Maximum Lifting capacity 2 tons | Set | 1 | 2.5m*2.5m*1.5m | ||
4 | Hopper top material distribution equipment | LQBL-4 | distribution material capacity 30T/h | Set | 2 | 2m*2m*1m | |
5 | Wind cap | FM-500 | Air pressure:19.6KPa,flowing capacity:20000 M3/h | Set | 2 | 0.8m*1.2m*1m | |
6 | Multi-ways dust discharging machine | LQCH-4 | Max.discharging capacity:30t/h,discharging temperature≤120ºC | Set | 4 | 1m*1.3m*0.5m | |
7 | Two section sealing valve | LQMF-3 | Max.dust discharging capacity:50t/h, | Set | 1 | 2m*1.5m*1.5m | |
working pressure≥0.3Mpa;dust discharging temperature≤120ºC | |||||||
8 | Electrical belt weigh feeder | DZC-3.0 | Range max3.0t;complete set | Set | 1 | ||
9 | Finished product belt | TD75 type | 4KW, B650 | Set | 1 | ||
10 | Revertive belt | TD75 type | 4KW B650 | Set | 1 | ||
11 | Raw meal belt | TD75 type | 5.5KW B650 | Set | 1 | ||
12 | Bucket Elevator | 80T/h | Set | 1 | |||
13 | Hanging vibrating feeder | ZG-100 | Motor 0.75KW×2 | Set | 2 | 1m*1.5m*0.8m | |
14 | Finished product screen | 100T/h | Set | 1 | |||
15 | Primary Fan | High pressure fan | Air Pressure10Kpa Air Volume 9000m3/h | Set | 1 | 1.8m*1.8m*1.0m | |
16 | Secondary Fan | High pressure fan | Air Pressure10Kpa Air Volume 13000 m3/h | Set | 1 | 2.0m*2.0m*1.5m | |
17 | Burner | KTRMS-80 | Temperature max300ºC,pressure:13 kPa | piece | 36 | ||
18 | Batterfly valve for burner | D341H | pressure resistance 1.0MPa | piece | 72 | ||
19 | Batterfly valve | D341H | DN400-500 (assistance gas) | Set | 2 | ||
20 | Ducting and support for fan | Set | 1 | Provide drawing to site | |||
Three | Additional Equipment For furnace | ||||||
1 | Dust Filter and Assembly Motor | Air flow capacity 40000 Nm3/h,Dust removing efficency>98,Dust emission<50mg/m3 | Set | 1 | |||
2 | Batterfly valve | D341H | DN800 (chimney ducting) | Set | 1 | ||
3 | Ducting Expansion piece | DN800(vertical chiemney ducting),expansion range ±50mm | Set | 2 | |||
4 | Ducting ,chimney,support,flange for dust filter | DN800 DN300 ducting | Set | 1 | |||
5 | Two sections gas calcining furnace | coal gas capacity 6300-8000Nm3/h. | Set | 2 | |||
including electric tar,coal gas dust filter | |||||||
6 | Coal gas pressure adding station | Pressure adding value12Kpa | Set | 1 | |||
7 | Adjustable batterfly valve for coal gas | Set | 1 | ||||
8 | Coal gas ducting | 1.0MPa | Set | 1 | |||
9 | Coal gas anti-explosion valve | Set | 4 | ||||
10 | Air compressor | P=0.8MPa | Set | 1 | 2m*2m*1.5m | ||
11 | Air Filter | Pipe connection diameter DN80,using pressure 0.05~1.0MPa | Set | 1 | |||
12 | Air tank | 1m3 P=0.8MPa ,outlet diameter ф80 | Set | 2 | |||
13 | Air comperssor ducting | DN20 DN25 DN50 DN80 | Set | 1 | |||
Four | Lime slaking line | ||||||
1 | Belt weight feeder | DZC-8.0 | Capacity max8.0t; | Set | 1 | ||
2 | Finished product belt | TD75 TYPE | 5.5KW, B650 | Set | 1 | ||
3 | Lime slaking machine | Ø1.5×15.9m | 11KW | ||||
Five | Electrical part | ||||||
1 | High Voltage electrical panel | Set | 1 | ||||
2 | Automatic and Instrumentation | Including DCS,Thermocouple,pressure transmitter,level sensor etc. | Set | 1 | |||
3 | Low voltage power assembly panel (including VFD) | Low voltage panel,soft starting panel,VFD panel | Set | 1 |